Offline, quiet and alarm rows
line-alarmmachine-offlinemachine-quietMACHINE_QUIET_MSMACHINE_OFFLINE_DEBOUNCE_MSA stopping alarm, a dropped machine and a silent one each become a row for the line operator, resolved when the machine recovers.
The situation
A machine raises an emergency stop, loses its network, or stays connected but stops reporting. Each needs a person, and each should clear itself when the machine is back, with a record of how long it took.
The recipe
Name the operator role on the line, and tune the timers in the environment:
{ "siteId": "site-1", "lineId": "line-1", "roles": { "operator": "line-operator" }, "machines": [{ "machineId": "cut-01", "process": "cut" }] }MACHINE_OFFLINE_DEBOUNCE_MS=15000MACHINE_QUIET_MS=90000| Row | Raised when | Resolved when |
|---|---|---|
line-alarm |
A critical or emergency alarm is raised | The machine clears it, with who cleared it. A person who resolves it first sends ack-alarm |
machine-offline |
Presence goes offline past the debounce | The machine is heard again |
machine-quiet |
A connected machine sends nothing for MACHINE_QUIET_MS |
It is heard again (0 turns this off) |
An alarm body may name its catalog edition, catalog: { domain, key, version }, so the row reads the code’s meaning as of that edition.
The guarantee
A replica taking the line reads back its open alarm, offline and quiet rows, then the machines’ retained state, so a clear or a return that happened while no gateway was listening still resolves its row. An alarm id reused with a new raise time counts as a new alarm. See Machines.
Related patterns
The physical world
Broken messages become rows
Under a strict codec a message that breaks the contract is confirmed, never acted on, and shown to an operator as a row.
The escalation boundary
Errors become escalations
When retries run out, the failure becomes a row an operator can act on. The run waits for retry or skip instead of disappearing.
Analytics
Park every state
Each state an item passes through is one escalation row. The queue becomes a complete time series of the process with no extra instrumentation.